1 VmAA10A¦¸VΩ10A¡ãC F ¡ã¡ã ¡ãOPERATING INSTRUCTIONS AUTORANGING DIGITAL MULTIMETER PDMT25 www.pyleaudio.com
10 4. DC/DC VOLTAGE MEASUREMENT 1.sert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2. S
11 test lead banana plug into the 10A jack. 5. Press the AC/DC button until “DC” appears in the display. 6. Remove power from the circuit under test,
12 AC CURRENT MEASUREMENT 1. Insert the black test lead plug into the negative (COM) socket. 2. For current measurements up to 10A, set the function s
13 indicate the proper decimal point, value and symbol. RESISTANCE [ Ω ] MEASUREMENT WARNING: To avoid electric shock, disconnect power to the unit un
14 CONTINUITY CHECK WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them. 1. Set the range switc
15 DIODE TEST WARNING: To avoid electric shock, do not test any diode that has voltage on it. 1. Set the function switch to the position. 2. Inser
16 CAPACITANCE MEASUREMENT WARNING: To avoid electric shock, discharge the capacitor under test before measuring. 1. Set the function switch to the CA
17 FREQUENCY MEASUREMENT 1. Set the function switch to the Hz position. 2. Insert the black test lead banana plug into the negative (COM) jack and t
18 5. Read the temperature in the display. Note: The temperature probe is fitted with a type K mini connector. A mini connector to banana connector ad
19 SPECIFICATIONS Technical: Insulation: Class2, Double insulation. Overvoltage category: CATIV 600V,CATIII 1000V NOTE: These meters meet CAT I
2 SAFETY WARNINGS The following safety information must be observed to insure maximum personal safety during the operation at this meter: Measure
20 Measurement rate: 2 times per second nominal. Auto power off: Meter automatically shuts down after approx. 30 minutes of inactivity. Operatin
21 DC Voltage (Auto-ranging) Range Resolution Accuracy 400.0mV 0.1mV 4.000V 1mV 40.00V 10mV 400.0V 100mV +0.5% of rdg + 2 digits 1000V 1V +0.8% of r
22 Range Resolution Accuracy 400.0uA 0.1uA 4000uA 1uA 40.00mA 10uA 400.0mA 100uA +1.2% of rdg + 3 digits 10A 10mA +2.5% of rdg + 3 digits Overload Pr
23 Resistance [Ω] (Auto-ranging) Range Resolution Accuracy 400.0Ω 0.1Ω +0.8% of rdg + 5 digits 4.000kΩ 1Ω 40.00kΩ 10Ω 400.0kΩ 100Ω +0.8% of rdg + 2 d
24 Frequency (Auto-ranging) Range Resolution Accuracy 4.000kHz 1Hz 40.00kHz 10Hz 400.0kHz 100Hz +1.2% of rdg + 3 dgts 40.00MHz 1kHz +1.5% of rdg + 4
25 Overload protection: 1000V dc or ac rms. Audible continuity Audible threshold: Less than35Ω Test current MAX. 1.5mA Overload protection: 1000V dc
26 WARNING: To avoid electric shock, do not operate your meter with the battery cover removed. BATTERY INSTALLATION WARNING: To avoid electric shock,
27 REPLACING THE FUSES WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the fuse /battery cover.
3 Replacement fuses must be of the correct type and rating. The instrument must not be used if any part of it is damaged. Warnings and precauti
4 This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result damage to the product. This symbol advises the use
5 SYMBOLS AND ANNUNCIATORS ))) Continuity BAT Low Battery Diode test HOLD Data Hold AUTO AutoRanging AC Alternating Current or Voltage DC Direct C
6 OPERATION To turn on the instrument turn the range knob from the OFF position to any measurement range. Note: For best battery life ALWAYS turn the
7 measurement for later reference. 1. Press the HOLD button to “freeze” the reading on the indicator. The “HOLD” message will be appear in the displa
8 Peak Hold button The Peak Hold function captures the peak AC or DC voltage or current. The meter can capture negative or positive peaks as fast as 1
9 for the new function selected. RANGE button When the meter is first turned on, it automatically goes into AutoRanging. This automatically selects th