Page view 8
9
for the new function selected.
RANGE button
When the meter is first turned on, it automatically goes
into AutoRanging. This automatically selects the best
range for the measurements being made and is
generally the best mode for most measurements. For
measurement situations requiring that a range be
manually selected, perform the following:
1. Press the RANGE button. The “Auto Range”
display indicator will turn off, The “Manual
Range” display indicator will turn on
2. Press the RANGE button to step through the
available ranges until you select the range you
want.
3. Press and hold the RANGE button for 2 seconds to exit
the ManualRanging mode and return to AutoRanging.